Skip to content

Supplying industry across the UAE, GCC, Middle East & Africa

Maintenance & Reliability

Single-Point Automatic Lubricators: When and How to Use Them

What automatic single-point lubricators do, the different types, where they pay off, how to choose the right lubricant and setting, and how to install and check them.

Single-Point Automatic Lubricators: When and How to Use Them

Key takeaways

  • Single-point automatic lubricators deliver small, regular amounts of grease or oil to one point over a set period.
  • They pay off at hard-to-reach, hazardous, critical and contamination-prone points.
  • Electromechanical units give more consistent output than gas-driven units, especially in varying temperatures.
  • Set the discharge period from the calculated grease quantity and interval, and use the right grease.
  • They still need checking: include them in routes and replace them on time.

A single-point automatic lubricator is a small, self-contained unit that screws onto a lubrication point and delivers grease or oil continuously or at regular intervals over a set period, typically from one to twelve months. Instead of a technician adding a large shot of grease every few weeks, the bearing receives small amounts all the time. This keeps the bearing and its seals properly lubricated, reduces contamination and saves labour. This guide explains how they work and where they pay off.

How do single-point lubricators work?

TypeHow it deliversNotes
Gas-driven (electrochemical)A chemical reaction produces gas that pushes a pistonSimple, low cost; output varies with temperature
Spring-drivenA spring pushes the pistonSimple; output depends on back-pressure
ElectromechanicalA battery-powered motor drives a pistonConsistent output, adjustable, higher pressure; reusable drive units
Multi-point electromechanicalOne unit feeds several points through linesFor groups of nearby points

Where do single-point lubricators pay off?

  • Hard-to-reach points: high fans, conveyor heads, bearings behind guards.
  • Hazardous locations: points that need permits, ladders or isolation to reach.
  • Critical bearings where missed lubrication is costly.
  • Dusty and wet locations, where continuous small amounts keep seals full.
  • Remote or unmanned sites, such as pump stations.
  • Points that are often forgotten or over-greased.

Benefits

BenefitWhy
More consistent lubricationSmall, regular amounts instead of large, infrequent shots
Less contaminationSeals stay full; nipples are not opened in dirty conditions
Less over-greasingDelivery rate matches the calculated need
Labour savingsFewer manual visits, especially to difficult points
SafetyFewer climbs, fewer entries into hazardous areas

How do you choose the discharge period?

Calculate how much grease the bearing needs over a period, then choose a lubricator size and setting to deliver it. For example, if a bearing needs 10 g of grease every two weeks, it needs about 260 g a year. A 250 ml unit set to 12 months would deliver roughly that amount. Use the bearing formula (0.005 × D × B grams) and the relubrication interval to calculate the need. See how much grease a bearing needs.

How do you choose the lubricant?

Use the same grease the bearing needs anyway, provided it is suitable for the lubricator: very stiff greases (NLGI 3) or greases with large solid particles may not dispense reliably, especially through long lines. NLGI 2 and softer greases are common. Many units are available pre-filled with standard greases, or can be filled with a specific product such as Mobilith SHC 220, PETAMO GY 193 or Mobilux EP 2. Check compatibility with the grease already in the bearing. See grease compatibility.

Temperature effects

Gas-driven units deliver faster when hot and slower when cold, because gas expansion depends on temperature. In GCC summers, a gas unit set for six months may empty much faster. Electromechanical units are less affected. Check the manufacturer’s temperature range and adjustment charts, and consider electromechanical units where temperatures vary widely.

Installation

  1. Purge the bearing with fresh grease using a grease gun, so the lubricator starts on a full bearing.
  2. Check that the grease path is clear: remove old, hardened grease and check that relief paths are open.
  3. Activate the lubricator and set the discharge period.
  4. Install it directly on the point, or remotely with a short line and suitable fittings.
  5. Label the unit with the installation date and expected replacement date.
  6. Record the installation in the lubrication schedule.

Remote mounting

Mounting the lubricator away from the bearing, with a feed line, protects it from heat, vibration and impact, and makes checking and replacing easier. Keep lines short, use the recommended line diameter, and pre-fill lines with grease. Long lines and stiff greases increase back-pressure; electromechanical units cope better with this.

Checking and replacing

  • Check units on regular routes: is the level falling as expected?
  • Look for fresh grease at the bearing seals.
  • Check for damage, leaks and blocked lines.
  • Replace or refill units before they run empty.
  • Adjust settings if bearings run hot or show signs of under- or over-lubrication.

Hazardous areas

In oil and gas, chemical and other hazardous areas, use lubricators certified for the area classification, for example under ATEX or IECEx schemes. Check the certification label before installing. See oil and gas lubrication.

Single-point or central lubrication system?

Single-point lubricators serve one point each, or a few points with multi-point units. Central lubrication systems serve many points from one pump through a network of lines and distributors, and are common on mobile equipment, presses, conveyors and large machines. Single-point units are quicker to install, need no infrastructure and suit scattered points. Central systems suit dense groups of points on one machine and offer monitoring and higher pressures. Many plants use both: central systems on large machines, single-point units on scattered critical points elsewhere.

Oil lubricators

Some single-point units dispense oil instead of grease, for example to chains, slides or open gears. They deliver small amounts of oil through a brush or nozzle at regular intervals. Choose the oil viscosity and type for the application, such as a chain oil, and position the brush or nozzle where the oil reaches the working surfaces, such as the gap between chain plates.

Records and replacement planning

Every lubricator should be listed in the lubrication schedule with its location, grease, size, setting, installation date and replacement date. Plan replacements in advance, and order units and refills with enough lead time. Some electromechanical units have indicators or connectivity that show status and remaining contents, which helps planning on large installations.

How do GCC conditions affect automatic lubricators?

High summer temperatures affect both the lubricator and the grease. Choose units rated for the ambient temperature, mount them out of direct sun where possible, and use greases suitable for the bearing temperature. In dusty sites, the sealed design of lubricators is an advantage: the lubrication point stays closed, and seals stay full of fresh grease.

Cost justification

Compare the cost of the lubricators and grease with the labour saved, especially at difficult points, the reduction in failures and the improvement in safety. For a fan bearing that needs a permit and a lift to reach, one avoided visit can pay for several lubricators. For easy, low-criticality points, manual lubrication may remain cheaper.

Starting a lubricator programme

  1. List candidate points: hard to reach, hazardous, critical or contamination-prone.
  2. Calculate grease needs and choose unit sizes and settings.
  3. Choose the grease, checking compatibility with the current product.
  4. Install a pilot group and check them closely for the first months.
  5. Adjust settings based on bearing temperatures and grease condition at seals.
  6. Roll out to further points and add all units to the lubrication schedule.

Starting with a pilot group builds experience and confidence before a larger rollout. Record bearing temperatures and seal condition at each check, so the results can be compared with manual lubrication on similar points.

A worked example: rooftop fans

A distribution centre in Abu Dhabi has 30 rooftop ventilation fans, each with two bearings, reached by ladder in high heat. Manual greasing is irregular and bearings fail every summer. The site installs electromechanical lubricators set for six months, mounted on brackets with short lines, filled with a high-temperature grease. Technicians check them monthly from a safe position and replace them twice a year. Bearing failures fall and roof access drops sharply.

What are the most common mistakes?

  • Installing on a dry or blocked bearing without purging first.
  • Choosing a discharge period without calculating the need.
  • Ignoring temperature effects on gas-driven units.
  • Using greases that are too stiff for the unit or line.
  • Installing and forgetting: units still need checking.

Frequently asked questions

How long do single-point lubricators last?

Typically from one to twelve months, depending on size and setting.

Can they be used with any grease?

Most NLGI 2 and softer greases work. Very stiff greases or those with large solids may not dispense reliably.

Are they worth it?

At hard-to-reach, hazardous or critical points, usually yes. For easy, non-critical points, manual greasing may be enough.

Do they work in hot climates?

Yes, if rated for the temperature. Electromechanical units are less affected by temperature than gas units.

Can they be used in hazardous areas?

Yes, if certified for the area classification.

What happens if a lubricator runs empty?

The bearing stops receiving fresh grease, and seals can dry out. Plan replacements before units empty and check levels on regular routes.

Can one lubricator feed two bearings?

Multi-point units or dividers can feed several points, but a single-point unit should normally feed one point so delivery to each bearing is assured.

Conclusion

Single-point automatic lubricators deliver small, regular amounts of grease to points that are hard to reach, hazardous, critical or contamination-prone. Calculate the need, choose the right unit and grease, purge before installing, and check them on routes. Used well, they reduce failures, labour and risk. Browse our synthetic long-term greases.

Need help applying this to your plant? Send us the equipment details or the product you use now and we will recommend a suitable Kluber or Mobil grade: request a quote and we reply within one business day.

Products mentioned in this guide

Mobil

Mobilith SHC 220

Extreme Pressure Grease

Viscosity
ISO VG 220
380g cartridge · 16kg bucket

Kluber

PETAMO GY 193

Long-term and high-temperature grease

Service temp.
-20 to 180 °C
Base oil @40 °C
160 mm²/s
Base oil
Ester oil
400g · 1kg · 25kg

Mobil

Mobilux EP 004

Lithium-based Semi-fluid Bearing Grease

Viscosity
ISO VG 150
18kg bucket

Mobil

Mobilux EP 3

Lithium-based Multipurpose Bearing Grease

Viscosity
ISO VG 150
18kg bucket

Send your requirement list. Receive one quotation within one business day.