Key takeaways
- The ISO VG number is the oil’s kinematic viscosity at 40 °C in mm²/s, with a tolerance of ±10%.
- Viscosity falls as temperature rises; the viscosity index (VI) shows how much.
- Always start from the equipment maker’s recommended grade, then check viscosity at the real operating temperature.
- Hydraulics typically use VG 32–68, enclosed gearboxes VG 150–680, and spindles VG 2–22.
- Synthetic oils usually have higher VIs, which keeps viscosity more stable in hot climates.
Every industrial oil is sold by viscosity grade: ISO VG 32, 46, 68, 100, 150, 220, 320, 460, 680 and so on. Choosing the right grade is the first and most important step in selecting a hydraulic, gear, circulating, compressor or spindle oil. Too thin, and the oil film breaks down, causing wear. Too thick, and the system wastes energy, runs hot, or suffers from poor flow at start-up. This guide explains what the numbers mean and how to use them.
The ISO viscosity grade system is defined in the international standard ISO 3448, published by ISO. It is used by every major lubricant maker, including Mobil and Kluber, which makes it the common language between equipment makers, maintenance teams and suppliers.
What is viscosity?
Viscosity is an oil’s resistance to flow, its “thickness”. For lubrication, viscosity determines how thick a film the oil forms between moving surfaces at a given speed and load. Industrial oils are specified by kinematic viscosity, measured in square millimetres per second (mm²/s), also called centistokes (cSt), using standard methods such as ASTM D445 or DIN 51562.
What does the ISO VG number mean?
The ISO VG number is the midpoint of the oil’s kinematic viscosity at 40 °C. The actual viscosity may be within ±10% of that midpoint. So an ISO VG 46 oil has a viscosity between about 41.4 and 50.6 mm²/s at 40 °C, and an ISO VG 220 oil between about 198 and 242 mm²/s.
| ISO VG | Viscosity range at 40 °C (mm²/s) | Typical applications |
|---|---|---|
| 2–10 | About 1.98–11.0 | High-speed spindles, very light mechanisms |
| 15–22 | About 13.5–24.2 | Spindles, light hydraulics, some compressors |
| 32 | 28.8–35.2 | Hydraulics, turbines, light circulating systems |
| 46 | 41.4–50.6 | Hydraulics, turbines, compressors |
| 68 | 61.2–74.8 | Hydraulics in hot conditions, slideways, compressors |
| 100–150 | 90–165 | Light gearboxes, circulating bearings, slideways |
| 220–320 | 198–352 | Most enclosed industrial gearboxes |
| 460–680 | 414–748 | Heavily loaded, slow or hot gearboxes, worm gears |
| 1000 and above | 900+ | Very heavy, slow gears and special applications |
How does viscosity change with temperature?
Viscosity falls as temperature rises, and it does so quickly. A typical mineral ISO VG 46 hydraulic oil might have a viscosity of about 46 mm²/s at 40 °C but only around 7 mm²/s at 100 °C. Because equipment rarely runs at exactly 40 °C, the viscosity at the actual operating temperature is what really matters.
Data sheets give viscosity at both 40 °C and 100 °C. From these two points, you can estimate viscosity at other temperatures using viscosity–temperature charts (based on ASTM D341), or simply ask your supplier.
What is viscosity index (VI)?
The viscosity index describes how much viscosity changes with temperature. A high VI means the oil’s viscosity stays more stable as it heats up and cools down. Conventional mineral oils typically have VIs around 95–105; many synthetic oils, such as PAO-based Mobil SHC products, have considerably higher VIs. A higher VI helps in two ways: the oil stays thick enough at high temperatures, and it is not too thick at cold starts.
In the GCC, where equipment can see large differences between cold, air-conditioned start-ups and very hot summer running, high-VI oils give a wider safe operating window.
How do you choose the right viscosity grade?
- Start with the equipment maker’s recommendation. Pump, gearbox, compressor and machine-tool makers specify a grade or a viscosity range for good reasons.
- Find the actual operating temperature. Measure oil temperature in the tank, sump or return line during normal and peak operation.
- Check viscosity at operating temperature. Make sure it stays within the range the equipment needs, for example the pump maker’s minimum and maximum viscosity.
- Consider start-up conditions. At the coldest start-up temperature, the oil must not be too thick for pumps and circulation.
- Adjust only with good reason. If temperatures are abnormal, fix cooling first; change grade only within the maker’s guidance.
Typical grades by application
| Application | Typical ISO VG range | Notes |
|---|---|---|
| Industrial hydraulics | 32–68 | Follow the pump maker’s viscosity window |
| Mobile hydraulics | 32–68 (sometimes multigrade) | Wide temperature range |
| Steam and gas turbines | 32–68 | Turbine oils with high oxidation stability |
| Circulating bearing systems | 68–220 | Depends on bearing speed and temperature |
| Enclosed spur/helical gearboxes | 150–460 | Depends on speed, load and temperature |
| Worm gearboxes | 220–680 | Often PAG synthetic oils |
| Machine-tool slideways | 32–220 | Slideway oils, e.g. Mobil Vactra |
| High-speed spindles | 2–22 | Spindle oils, e.g. Mobil Velocite |
| Air compressors | 32–100 | Compressor oils per compressor maker |
ISO VG and other viscosity systems
ISO VG is the standard for industrial oils. Automotive engine oils use SAE J300 grades (such as 10W-40), and automotive gear oils use SAE J306 grades (such as 80W-90). AGMA lubricant numbers are sometimes used for industrial gear oils in older specifications. These systems are not interchangeable; if an equipment manual uses a different system, ask your supplier to convert it to the equivalent ISO VG.
How do hot climates affect the viscosity you need?
High ambient temperatures in the UAE and the GCC raise oil temperatures, which lowers viscosity. Hydraulic systems, gearboxes and compressors that are borderline in cooler climates can run with too thin an oil in summer. The right response is usually to check and improve cooling, consider a higher-VI synthetic oil, and only then, if the equipment maker allows, consider a higher grade. Our guide on choosing hydraulic oil for hot climates explains this in detail.
Can you mix viscosity grades?
Mixing two grades of the same product family produces an intermediate viscosity, but it is rarely a good idea in practice: it makes the actual viscosity uncertain and complicates oil analysis. Mixing different products or base-oil types can cause additional problems. Keep one product and grade per system.
Monitoring viscosity in service
Oil viscosity can change in service: it rises as oil oxidises or is contaminated with heavier oil, and falls if a thinner oil is added or the oil is diluted. Oil analysis checks viscosity against the new-oil value; a change of more than about 10% is usually a warning sign. See oil analysis basics.
Worked example: is VG 46 thick enough at 70 °C?
A hydraulic pump maker specifies a minimum operating viscosity of 16 mm²/s and an optimum range of 16–36 mm²/s. The system runs at 70 °C in summer. A typical mineral VG 46 oil, around 46 mm²/s at 40 °C and about 7 mm²/s at 100 °C, has a viscosity in the region of the upper teens at 70 °C. That is inside the window, but close to the minimum. If summer temperatures push the oil to 80 °C, viscosity falls further and the pump may run below its minimum. Options include improving cooling, using a higher-VI synthetic oil, or moving to VG 68 if the cold-start viscosity is still acceptable.
Figures like these vary by product; always use the actual data sheet values and a viscosity–temperature chart, or ask your supplier to do the calculation.
Viscosity and energy efficiency
Thicker oils need more energy to pump and to shear. In hydraulic systems and gearboxes, running an unnecessarily high viscosity increases power consumption and operating temperature. Running too low a viscosity increases internal leakage and wear. The most efficient choice is the lowest viscosity that still protects the equipment at its highest operating temperature, which is another reason high-VI oils are popular: they allow a lower grade without losing protection when hot.
Quick troubleshooting by viscosity
| Symptom | Possible viscosity-related cause |
|---|---|
| Pump noise or cavitation at start-up | Oil too viscous when cold |
| Sluggish actuators when hot, rising leakage | Oil too thin at operating temperature |
| Gearbox running hot, high power draw | Viscosity too high for speed, or overfilled |
| Gear pitting or scuffing | Viscosity too low for load and temperature |
| Oil analysis shows viscosity change over 10% | Wrong oil added, oxidation or contamination |
What are the most common mistakes?
- Choosing a grade “one up” for safety without checking the equipment maker’s range.
- Ignoring the actual operating temperature.
- Confusing ISO VG with SAE grades.
- Topping up with a different grade.
- Assuming all oils of the same VG behave the same, whatever their VI or additives.
Browse our hydraulic oils, gear oils, circulating oils and machine-tool oils.
Frequently asked questions
Is ISO VG the same as SAE grades?
No. SAE grades are used mainly for engine and vehicle gear oils and are defined differently. Industrial equipment normally specifies ISO VG.
Can I use a higher viscosity than specified?
Only with care. Too high a viscosity can cause start-up problems, pump cavitation, more heat and lower efficiency. Follow the equipment maker’s range.
What does VI mean on a data sheet?
Viscosity index: how much the viscosity changes with temperature. Higher is more stable.
Why is my oil’s viscosity different from the ISO VG number?
ISO VG allows ±10% around the midpoint at 40 °C, and viscosity changes in service with oxidation and contamination.
Which grade is ISO VG 46 in Mobil’s hydraulic range?
For example, Mobil DTE 25 Ultra and Mobil DTE 10 Excel 46 are ISO VG 46 grades.
Conclusion
ISO VG grades give industrial oils a common, precise language: the number is the viscosity at 40 °C. Choosing the right grade means starting from the equipment maker’s recommendation, checking viscosity at the real operating temperature, and considering the viscosity index, especially in hot climates. Get the grade right, keep one product per system, and monitor viscosity in service.
Need help applying this to your plant? Send us the equipment details or the product you use now and we will recommend a suitable Kluber or Mobil grade: request a quote and we reply within one business day.